ABSTRACT
INTRODUCTION: Brugada syndrome (BrS) has a dynamic ECG pattern that might be revealed by certain conditions such as fever. We evaluated the incidence and management of ventricular arrhythmias (VAs) related to COVID-19 infection and vaccination among BrS patients carriers of an implantable loop recorder (ILR) or implantable cardioverter-defibrillator (ICD) and followed by remote monitoring. METHODS: This was a multicenter retrospective study. Patients were carriers of devices with remote monitoring follow-up. We recorded VAs 6 months before COVID-19 infection or vaccination, during infection, at each vaccination, and up to 6-month post-COVID-19 or 1 month after the last vaccination. In ICD carriers, we documented any device intervention. RESULTS: We included 326 patients, 202 with an ICD and 124 with an ILR. One hundred and nine patients (33.4%) had COVID-19, 55% of whom developed fever. Hospitalization rate due to COVID-19 infection was 2.76%. After infection, we recorded only two ventricular tachycardias (VTs). After the first, second, and third vaccines, the incidence of non-sustained ventricular tachycardia (NSVT) was 1.5%, 2%, and 1%, respectively. The incidence of VT was 1% after the second dose. Six-month post-COVID-19 healing or 1 month after the last vaccine, we documented NSVT in 3.4%, VT in 0.5%, and ventricular fibrillation in 0.5% of patients. Overall, one patient received anti-tachycardia pacing and one a shock. ILR carriers had no VAs. No differences were found in VT before and after infection and before and after each vaccination. CONCLUSIONS: From this large multicenter study conducted in BrS patients, followed by remote monitoring, the overall incidence of sustained VAs after COVID-19 infection and vaccination is relatively low.
Subject(s)
Brugada Syndrome , COVID-19 , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/epidemiology , Brugada Syndrome/therapy , Retrospective Studies , Incidence , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/prevention & control , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/therapy , Registries , Vaccination , Follow-Up StudiesABSTRACT
BACKGROUND: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of patients with symptomatic atrial fibrillation (AF). AF symptoms are highly subjective; however, they are important outcomes for the patient. The aim is to describe the use and impact of a web-based App to collect AF-related symptoms in a population of patients who underwent PVI-C in seven Italian centers. METHODS: A patient App to collect AF-related symptoms and general health status was proposed to all patients who underwent an index PVI-C. Patients were divided into two groups according to the utilization of the App or the non-usage. RESULTS: Out of 865 patients, 353 (41%) subjects composed the App group, and 512 (59%) composed the No-App group. Baseline characteristics were comparable between the two cohorts except for age, sex, type of AF, and body mass index. During a mean follow-up of 7.9±13.8 months, AF recurrence was found in 57/865 (7%) subjects with an annual rate of 7.36% (95% CI:5.67-9.55%) in the No-App versus 10.99% (95% CI:9.67-12.48%) in the App group, p=0.007. In total, 14,458 diaries were sent by the 353 subjects in the App group and 77.1% reported a good health status and no symptoms. In only 518 diaries (3.6%), the patients reported a bad health status, and bad health status was an independent parameter of AF recurrence during follow-up. CONCLUSIONS: The use of a web App to record AF-related symptoms was feasible and effective. Additionally, a bad health status reporting in the App was associated with AF recurrence during follow-up.
ABSTRACT
From 2020, many countries have adopted several restrictions to limit the COVID-19 pandemic. The forced containment impacted on healthcare organizations and the everyday life of patients with heart disease. We prospectively analyzed data recorded from implantable defibrillators and/or cardiac resynchronization devices of Italian patients during the lockdown (LDP), post-lockdown period (PLDP) and a control period (CP) of the previous year. We analyzed device data of the period 9 March 2019-31 May 2020 of remotely monitored patients from 34 Italian centers. Patients were also categorized according to areas with high/low infection prevalence. Among 696 patients, we observed a significant drop in median activity in LDP as compared to CP that significantly increased in the PLDP, but well below CP (all p < 0.0001). The median day heart rate and heart rate variability showed a similar trend. This behavior was associated during LDP with a significant increase in the burden of atrial arrhythmias (p = 0.0150 versus CP) and of ventricular arrhythmias [6.6 vs. 1.5 per 100 patient-weeks in CP; p = 0.0026]; the latter decreased in PLDP [0.3 per 100 patient-weeks; p = 0.0035 vs. LDP]. No modifications were recorded in thoracic fluid levels. The high/low prevalence of COVID-19 infection had no significant impact. We found an increase in the arrhythmic burden in LDP coupled with a decrease in physical activity and heart rate variability, without significant modifications of transthoracic impedance, independent from COVID-19 infection prevalence. These findings suggest a negative impact of the COVID-19 pandemic, probably related to lockdown restrictions.
Subject(s)
Arrhythmias, Cardiac/etiology , COVID-19/complications , Heart Conduction System/physiopathology , Heart Rate , Hospitalization , Action Potentials , Aged , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , COVID-19/diagnosis , Female , Humans , Italy , Male , Middle Aged , Prognosis , Time Factors , COVID-19 Drug TreatmentABSTRACT
BACKGROUND: The COVID-19 pandemic has challenged the ability of health care organisations to provide adequate care. We report the experience of a national tertiary electrophysiology centre in the management of patients with cardiac implantable electronic devices (CIEDs) through the use of a fully remote follow-up model. METHODS: We daily and prospectively collected remote monitoring (RM) relevant findings and following clinical actions performed from March 10th to April 3rd 2020, a period of suspension of routine ambulatory activity due to the national lockdown. RESULTS: During the study period (25 days), we received 2,215 transmissions from 2,955 devices. Among them, 129 patients reported potential clinically actionable RM observations (event rate: 12.0/1000 patient-week). In 77 patients (60%), RM events triggered a clinical action, but only 5 patients needed an urgent in-hospital access (4 urgent procedures and 1 device reprogramming). CONCLUSIONS: In the unprecedented COVID-19 pandemic, RM became an essential tool in healthcare delivery for CIED patients. We observed that RM was effective in "keep people safe" and "focus only on individuals with health care needs".